Installation guide

Rack-Mountable Server Installation 2-25
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant 6400R Setup and Installation Guide Comments:
Part Number: 388776-002 File Name: c-ch02 Rack-Mountable Server Installation Last Saved On: 3/17/00 1:41 PM
IMPORTANT: After power is first applied to a power supply, booting begins after a 10-
second delay.
If you insert a System Configuration, Diagnostics, or SmartStart and Support
Software CD in the CD-ROM drive before powering on the server, the system
ROM boots to that utility. If the system ROM does not detect one of the CDs,
you are prompted for your intended operating system. The system will reboot
if any operating system-dependent configurations have changed with the new
operating system selection. If the selected operating system-dependent
configurations are the same as the current configurations, the system will boot
normally. If you enter a wrong choice, you can select another operating system
during subsequent reboots.
Powering Down the Server
The system power in the ProLiant 6400R server does not shut off completely
with the front panel Power On/Standby switch. The two positions of the switch
function as on and standby, instead of on and off. The standby position
removes power from most of the electronics and drives, but portions of the
power supply and some internal circuitry remain active.
To remove all power from the system, disconnect all power cords from the
server.
WARNING: To reduce the risk of electric shock or damage to
the equipment, disconnect power from the server by
unplugging all power cords from either the electrical outlet or
the server.
NOTE: Microsoft Windows NT users may use the Compaq Power Down Manager to power
down the server. For information, refer to the NTREADME.HLP file on diskette 1 of the
NTSSD.
1. Press the Power On/Standby switch to standby.
2.
Verify that the system LED on the front panel, near the
Power On/Standby switch, turns off and that all fans stop spinning.
3.
Disconnect all power cords from the server to remove all power.