Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index
Diagnostic Tools 3-21
For use with Pentium II and Pentium III Xeon processor-based servers only
Diagnostics Software
Test Error Codes Tables include all test error codes generated by Compaq products. Each code
has a corresponding description and recommended action(s). The system generates only those
codes that are applicable to the configuration and options.
When you select Diagnostics and Utilities from the System Configuration Utility main menu,
the utility prompts you to test, inspect, upgrade, and diagnose the server.
Diagnostics and Utilities are located on the system partition on the hard drive and must be
accessed when a system configuration error is detected during the Power-On Self-Test (POST).
Compaq Diagnostics software is also available on the Compaq SmartStart and Support Software
CD. You can create a Diagnostics diskette from the SmartStart and Support Software CD and
run Diagnostics from diskette.
The following options are available from the Diagnostics and Utilities menu:
■ Test Computer
■ Inspect Computer
■ Upgrade Firmware
■ Remote Utilities
■ Diagnose Drive Array
Diagnostic error codes are generated when the Diagnostics software recognizes a problem.
These error codes help identify possible defective subassemblies.
Steps for Diagnostics
In each case, the Recommended Action column lists the steps necessary to correct the problem.
After completing each step, run the Diagnostics utility to verify that the error condition has been
corrected. If the error code reappears:
1. Perform the next step listed in the table.
2. Run the Diagnostics program again.
3. Follow this procedure until the Diagnostics program no longer detects an error condition.