Specifications

Table Of Contents
3-20 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem Recommended Action
1798-Drive Array -
Array Accelerator
Write Error Occurred.
Array Accelerator is
disabled.
None Hard parity error while writing
data to posted-writes memory.
Enable Array Accelerator.
1799-Drive Array -
Drive(s) Disabled due
to Array Accelerator
Data Loss.
Select "F1" to
continue with logical
drives disabled.
Select "F2" to accept
data loss and to re-
enable logical drives.
None Volume failed due to loss of data
in posted-writes memory.
Press F1 to continue with
logical drives disabled or F2 to
accept data loss and re-enable
logical drive.
Beeps only: 2 Long 2L No valid memory is present in
the system.
Replace failed memory with
valid memory.
Beeps only: 2 Long +
2 Short
2L, 2S Power is cycled. Temperature too
hot. Processor fan either not
installed or not spinning.
Check fans.
(Run System
Configuration Utility -
F10 key)
None A configuration error occurred
during POST.
Press F10 to run System
Configuration Utility.
(RESUME - F1 key)
None As indicated to continue.
Press F1