Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index

Diagnostic Tools 3-11
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem Recommended Action
601-Diskette
Controller Error
None Diskette controller circuitry
failure.
1. Make sure the diskette
drive cables are attached.
2. Replace the diskette drive
and/or cable.
3. Replace the system board.
605-Diskette Drive
Type Error
2S Mismatch in drive type. Run the System Configuration
Utility to set diskette type
correctly.
1151-Com Port 1
Address Assignment
Conflict
2S Both external and internal serial
ports are assigned to COM1.
Run the System Configuration
Utility and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S Both external and internal serial
ports are assigned to COM2,
COM3, or COM4.
Run the System Configuration
Utility and correct.
1610-Temperature
violation detected.
Waiting for system to
cool
2S Ambient system temperature too
hot.
Check fan in system
environment.
1611-Fan failure
detected
2S Required fan either not installed
or not spinning.
Check fans.
1611-I/O Fan (Fan X)
failure detected
2S I/O fan has failed. Replace the failed fan.
1611-CPU Fan
(Fan X) failure
detected
2S CPU fan has failed. Replace the failed fan.
1612-Primary power
supply failure
2S Primary power supply has failed. Replace power supply as soon
as possible.
1613-Low System
Battery
None Real-time clock system battery is
running low on power.
Run Diagnostics. Replace failed
assembly as indicated.
1615-Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X
None A power supply has failed. Replace or check specified
power supply.
1617-Fan controller
not responding
2S Fan controller failure. Check and replace failed
controller assembly.
1617-I/O Fan
controller not
responding
2S I/O Fan controller failure. Check and replace failed
controller assembly.
continued