Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index

Removal and Replacement Procedures 2-25
For use with Pentium II and Pentium III Xeon processor-based servers only
Power Switch with LED
WARNING: To completely remove all power from the system, you must disconnect the power
cord from the server. In systems with multiple power supplies, you must disconnect all the
power cords to completely remove power from the system.
To remove the power switch from the Compaq ProLiant 5500 and 5500R:
1. Perform the preparation procedures. See "Preparation Procedures" earlier in this chapter.
2. Remove the fixed front bezel. See "Fixed Front Bezel" earlier in this chapter.
3. Remove the side access panel. See "Side Access Panel" earlier in this chapter.
4. Remove the top access panel. See "Top Access Panel" earlier in this chapter.
5. Remove fans. See “Fans” earlier in this chapter.
6. Unplug the power switch cable from the peripheral board.
7. Unplug the power LED from the front wall.
8. Press on the top and bottom of the switch from inside the chassis , and pull the switch
assembly out the front of the server .
2
1
1
Figure 2-19. Removing the power switch
Reverse steps 1 through 8 to replace the power switch.










