Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index

2-14 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Media Storage
Compaq ProLiant 5500 and 5500R Servers can house up to 14 media devices, including:
■ A preinstalled 3.5-inch 1.44-MB diskette drive
■ Two half-height drive bays (removable media area)
■ Preinstalled 24X or greater IDE CD-ROM drive
■ Hot-Plug SCSI Drive Cage: 10 Ultra2 drives
!"Simplex Mode: seven 1-inch drives or six 1.6-inch drives
!"Duplex Mode: eight 1-inch drives or six 1.6-inch drives (optional)
NOTE: Compaq ProLiant 5500 and 5500R Servers ship as tower or rack models. Figure 2-9 shows both
ProLiant models, and together with Table 2-1, shows the drive bay locations.
2
3
4
6
5
4
3
2
1
1
8 7
Figure 2-9. Server drive bay locations, rack, tower
NOTE: Wide Ultra drive cage is shown on rack view.










