Specifications

Table Of Contents
5-2 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
System Unit
Table 5-1
System Unit Specifications
U.S. Metric
Dimensions
Height 19 in 48.3 cm
Depth 24.5 in 30.5 cm
Width 12 in 62.2 cm
Weight with one power supply and no hard drive 90 lb 40.9 kg
Input Requirements Low range High range
Rated Input Voltage 100 to 120 V 200 to 240 V
Rated Input Frequency 50 to 60 Hz 50 to 60 Hz
Input Power 780W @ 110 VAC/1100W @ 220 VAC
Rated Input Current 8 A 6 A
Power Supply Output Power Low range High range
Rated Steady-State Power 500 W 750 W
Maximum Peak Power 540 W 780 W
Temperature Range
Operating 50° to 95°F 10° to 35°C
Non-operating -20° to 140°F -30° to 60°C
Shipping -22° to 122°F -30° to 60°C
Relative Humidity (noncondensing)
Operating 20% to 80% 20% to 80%
Nonoperating 5% to 90% 5% to 90%
Maximum Wet Bulb Temperature 101.7°F 38.7°C
Acoustic Noise NPEL (BELS) Average SPL (dBA)
Idle (fixed disk drives spinning) 6.0 43
Operating (random seeks to fixed disks) 6.1 44
Heat Dissipation 2594 BTU/h 3754 BTU/h