Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index

Diagnostic Tools 3-61
For use with Pentium II and Pentium III Xeon processor-based servers only
Server Health Logs
In some servers, Server Health Logs are replaced by the IML, if it is supported. See “Integrated
Management Display” in this chapter for more information.
Server Health Logs contain information to help identify and correct any server failures and
correlate hardware changes with server failure. Server Health Logs are stored in nonvolatile
RAM and consist of the Critical Error Log and the Revision History Table.
If errors occur, information about the errors is automatically stored in the Critical Error Log.
Whenever boards or components (that support revision tracking) are updated to a new revision,
the Revision History Table is updated.
ASR-2 Integrated Management Log Messages
The Integrated Management Log (IML) (or Critical Error Log for Server Health Logs) records
memory errors, as well as catastrophic hardware and software errors that cause the system to
fail. This information helps you quickly identify and correct the problem, thus minimizing
downtime.
You can view the IML (or Critical Error Log) through the Compaq Insight Manager. The
Diagnostics Utility either resolves the error or suggests corrective action in systems that do not
support event logs.
The IML (or Critical Error Log) identifies and records all the following errors. Each error type
is explained below.
Table 3-26
ASR-2 IML or Critical Error Log Messages
Message Description
Abnormal Program Termination The operating system has encountered an abnormal situation that has
caused a system failure.
ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM.
ASR-2 Test Event The System Configuration Utility generated a test alert.
Automatic Server Recovery
Base Memory Parity Error
The system detected a data error in base memory following a reset due to
the Automatic Server Recovery-2 (ASR-2) timer expiration.
Automatic Server Recovery
Extended Memory Parity Error
The system detected a data error in extended memory following a reset
due to the ASR-2 timer expiration.
Automatic Server Recovery
Memory Parity Error
The system ROM was unable to allocate enough memory to create a stack.
Then, it was unable to put a message on the screen or continue booting
the server.
Automatic Server Recovery
Reset Limit Reached
The maximum number of system resets due to ASR-2 timer expiration has
been reached, resulting in the loading of Compaq Utilities.
Battery Failing Low system battery warning. Replace battery within 7 days to prevent loss
of nonvolatile configuration memory. Failure of the battery supporting the
system’s nonvolatile RAM is imminent.
continued