Specifications
Table Of Contents
- Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
- Notice
- Contents
- About This Guide
- Chapter 1: Illustrated Parts Catalog
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols in Equipment
- Preparation Procedures
- Caster Mounting Plate (Tower)
- Front Bezel Door (Tower)
- Fixed Front Bezel
- Side Access Panel
- Top Access Panel
- U-Channel Access Panel
- Fans
- Media Storage
- SCSI and CD-ROM Cable Connection Diagram
- Integrated Management Display (IMD)
- Power Switch with LED
- Processor, Processor Power Module, and Terminator Board Locations
- Processor Removal
- Processor Power Module
- Processor Terminator Modules
- Peripheral Board
- Memory
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Network Interface Controller (NIC)
- Hot-Plug Power Supply LED Indicators
- Hot-Plug Power Supply Cover Plate
- Power Backplane Board
- System I/O Board with Tray
- External Replacement Battery
- Chapter 3: Diagnostic Tools
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- Power-On Self-Test (POST)
- Diagnostics Software
- Steps for Diagnostics
- 100 – 199, Primary Processor Test Error Codes
- 200 – 299, Memory Test Error Codes
- 300 – 399, Keyboard Test Error Codes
- 400 – 499, Parallel Printer Test Error Codes
- 500 – 599, Video Display Unit Test Error Codes
- 600 – 699, Diskette Drive Test Error Codes
- 800 – 899, Monochrome Video Board Test Error Codes
- 1100 – 1199, Serial Test Error Codes
- 1200 – 1299, Modem Communications Test Error Codes
- 1700 – 1799, Hard Drive Test Error Codes
- 1900 – 1999, Tape Drive Test Error Codes
- 2400 – 2499, Advanced VGA Board Test Error Codes
- 6000 – 6099, Compaq Network Interface Controller Boards Test€Error Codes
- 6500 – 6599, SCSI Hard drive Test Error Codes
- 6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
- 6700 – 6799, SCSI Tape Drive Test Error Codes
- 7000 – 7099, Server Manager/R Board Test Error Codes
- 8600 – 8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility (ADU)
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, LEDs, and Jumpers
- Chapter 5: Physical and Operating Specifications
- System Unit
- Dual Inline Memory Modules (DIMMs)
- 1.44-MB Diskette Drive
- 24X or Greater IDE CD-ROM Drive
- Integrated Dual-Channel Wide Ultra SCSI Controller
- 64-bit Dual Channel Wide Ultra2 SCSI Adapter
- Smart Array 3200 Controller
- Compaq 10/100 TX PCI Intel UTP Controller (NIC)
- Compaq 10/100 TX PCI UTP Controller (NIC)
- Non-Hot-Plug Ultra2 Hard Drives
- Non-Hot-Plug Wide-Ultra Hard Drives
- Hot Plug Ultra2 Hard Drives
- Hot-Plug Wide-Ultra Hard Drives
- Index

3-50 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-22
Event Messages
continued
Event Type Event Message Action
Processor
Correctable Error
Threshold exceeded
Processor Correctable error Threshold passed
(Slot X, Socket X)
Uncorrectable Error Unrecoverable Host Bus Data Parity Error
Host Bus Error Unrecoverable Host Bus Address Parity Error
EISA Bus
EISA Expansion Bus Master Timeout (Slot X)
EISA Expansion Bus Slave Timeout
EISA Expansion Board Error (Slot X)
EISA Expansion Bus Arbitration Error
Power down server and
replace EISA board
PCI Bus Error
PCI Bus Error (Slot X, Bus X, Device X,
Function X)
Power down PCI slot and
replace board
Power Subsystem
Power Supply Failure System Power Supply Failure (Power Supply X) Replace power supply
Power Supply Inserted System Power Supply Inserted (Power Supply X) None
Power Supply Removed System Power Supply Removed (Power
Supply X)
None
Power Supply
Not Redundant
System Power Supplies Not Redundant Add power supply
System Configuration
Battery Low
Real-Time Clock Battery Failing Replace Battery
Power Module Failure A CPU Power Module (System Board, Socket X) Replace power module
Power Module Failure A CPU Power Module (Slot X, Socket X) Replace power module
Power Modules Not
Redundant
System Power Modules Not Redundant Add power module
AC Voltage Problem System AC Power Problem (Power Supply X)
Power AC Overload System AC Power Overload (Power Supply X)
Automatic Server Recovery -2
System Lockup ASR Lockup Detected: Cause
Operating System
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
System Crash
Abnormal Program Termination: Cause
[NetWare]
Refer to the documentation
for the operating system.
Automatic Operating System Shutdown Initiated
Due to Fan Failure
Automatic Operating System Shutdown Initiated
Due to Overheat Condition
Automatic OS Shutdown
Fatal Exception (Number X, Cause)
Refer to the documentation
for the operating system.