Technical data
Example 4-16: Setting the Device Unit Number for the BOS Installation Disk
P00>>> wwidmgr -quickset -udid 101
Disk assignment and reachability after next initialization:
6008-05f3-0001-27e0-0000-0000-ca7b-0075
1
via adapter: via fc nport: connected: 2
dga101.1001.0.7.0 3 pga0.0.0.7.0 4 5008-05f3-0001-bd51 5 Yes
dga101.1002.0.7.0 pga0.0.0.7.0 5008-05f3-0001-bd59 No
dgb101.1001.0.8.0 pgb0.0.0.8.0 5008-05f3-0001-bd51 Yes
dgb101.1002.0.8.0 pgb0.0.0.8.0 5008-05f3-0001-bd59 No
The wwidmgr -quickset command provides a reachability display
equivalent to entering the wwidmgr -show reachability
command. The reachability part of the display provides the
following information:
1 The worldwide name (WWN) for the storage unit that is to be
accessed. This WWN is assigned to a wwidn variable.
2 In the connected column, whether the storage unit is
currently available through the Fibre Channel host bus
adapter to controller port connection.
3 The new device name for the storage unit.
4 The Fibre Channel adapters through which a connection to the
storage unit is potentially available.
5 The port WWN of the controller ports (N_Ports) that will be
used to access the storage unit. This will show up as an Nn
variable.
b. Set the device unit number for the first cluster member system boot
disk to 106, as shown in Example 4-17.
Example 4-17: Setting the Device Unit Number for the First Cluster Member
Boot Disk
P00>>> wwidmgr -quickset -udid 106
Disk assignment and reachability after next initialization:
6008-05f3-0001-27e0-0000-0000-ca7b-0075
via adapter: via fc nport: connected:
dga101.1001.0.7.0 pga0.0.0.7.0 5008-05f3-0001-bd51 Yes
dga101.1002.0.7.0 pga0.0.0.7.0 5008-05f3-0001-bd59 No
dgb101.1001.0.8.0 pgb0.0.0.8.0 5008-05f3-0001-bd51 Yes
dgb101.1002.0.8.0 pgb0.0.0.8.0 5008-05f3-0001-bd59 No
4-24 Preparing the MSA1000 for TruCluster Server Use