Technical data
Configuration Procedures 5–13
12. Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology. The following display is a sample result of a
SHOW THIS command, with the
areas of interest in bold.
Controller:
HSG80 (C) DEC ZG09030200 Software V8.6F-1, Hardware E11
NODE_ID = 5000-1FE1-0000-0000
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for dual-redundancy with 2GOPO30245
Device Port SCSI address 7
Time: 10-Mar-2001:12:30:34
Command Console LUN is lun 0
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0001
PORT_1_TOPOLOGY = FABRIC (standby)
Address = 210313
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0002
PORT_2_TOPOLOGY = FABRIC (fabric up)
Address = 210513
NOREMOTE_COPY
.......
.......
13. Turn on the switches if not done previously.
If you want to communicate with the FC switches through Telnet, set an IP address for
each switch. See the manuals that came with the switches for details.
Plug in the FC Cable and Verify Connections
14. Plug the FC cable from the first host adapter into the switch. Enter a SHOW CONNECTIONS
command to view the connection table:
SHOW CONNECTIONS