User guide

Managing serial console switches 121
2.
Select a port, and click Modify. The Modify Port dialog box appears.
3. To change the session time-out, enter a value in the Session Timeout field in the range of 1 to 90.
-or-
Choose a value from the pull-down menu. If you choose Global Setting, the values specified in the
Sessions category are used.
4. To change the CLI access character, enter a caret (^) and a character in the CLI Access Characters
field. The character entered after the caret can be a letter or one of the following: left bracket ([),
right bracket (]), caret (^), underscore (_), or backslash (\). To change the CLI access character,
enter a single character in the CLI Access Character field. The caret represents the <Ctrl> key, and in
combination with the next character can be used to access the console switch CLI mode during a
server session. ^D or <Ctrl>D is the default.
-or-
Choose a value from the dropdown list. If you choose Global Setting, the value specified in CLI
category are used.
NOTE: If you are modifying the dedicated CLI port (console port), then the CLI Access Character field is
disabled.
5. Enter a value in the range of 3000 to 65000 in the Telnet Port Number field to change the Telnet
port number.
6. Select a value from the dropdown menu in the Baud Rate field to change the baud rate.
7. Select a value from the dropdown menu in the Data Bits field to change the number of data bits.
8. Select a value from the dropdown menu in the Parity field to change the parity.
9. Select a value from the dropdown menu in the Stop Bits field to change the number of stop bits.
10. Select a value from the dropdown menu in the Flow Control field o change the flow control method.
This value cannot share the same signal as the Power On Signal value.
11. Select a value from the dropdown menu in the Toggle Signal field to change the toggle signal.