Specifications
Chapter 2
Removal and Replacement Procedures
This chapter provides subassembly/module-level removal and replacement procedures for
ProLiant DL380 Generation 2 servers. After completing all necessary removal and replacement
procedures, run the Diagnostics program to verify that all components operate properly.
You need the following items for some procedures:
■ Torx T-15 screwdriver
■ Diagnostics Utility from the Compaq SmartStart™ for Servers CD
Safety Considerations
Before performing service procedures, review the following safety information.
Electrostatic Discharge
A discharge of static electricity can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary to prevent damage. To prevent electrostatic
damage, observe the following precautions:
■ Transport products in static-safe containers such as conductive tubes, bags, or boxes.
■ Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
■ Cover workstations with approved static-dissipating material. Use a wrist strap connected
to the work surface and properly grounded tools and equipment.
■ Keep the work area free of nonconductive materials such as ordinary plastic assembly aids
and foam packing.
■ Always be properly grounded when touching a static-sensitive component or assembly.
■ Avoid touching pins, leads, or circuitry.
■ Always place drives PCB assembly-side down.
■ Use conductive field service tools.