User guide
Array Configuration Utilities 6-31
Auto-configuration
If no logical drives are configured, a CPQONLIN auto-configuration wizard
(Figure 6-25) appears and prompts you to select fault tolerance information.
CPQONLIN then configures arrays optimally for the selected fault tolerance.
Figure 6-25. Auto-configuration wizard with RAID 1 fault tolerance selected
Custom Configuration
Custom configuration allows you to create arrays and to assign fault tolerance
one array at a time. To custom configure an array, make selections from the
Main Configuration View screen. Highlight the controller, array, or logical
drive you want to configure. Make a selection from the Options menu located
on the right side of the screen. Figure 6-26 shows the controller highlighted on
the left side of the screen and Controller Options on the right side of the
screen.