Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
3-13
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code Beeps Probable Source of
Problem
Action
1773-Primary Fixed
Disk Port
Assignment
Conflict
None Fixed disk drive error. Run the System
Configuration Utility
and correct.
1776-Drive Array -
SCSI Port
Termination Error
None External and internal
SCSI drives are both
configured to Port 1.
Re-configure drives.
1777-Drive Array
Error
None Cooling fan failure,
internal temperature
alert or open cover.
Inspect for cooling fan
failure or open cover.
1778-Drive Array
resuming
Automatic Data
Recovery process
None This message appears
whenever a controller
reset or power cycle
occurs while Automatic
Data Recovery is in
progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
None Intermittent drive
failure and/or possible
loss of data.
If this message appears
and drive
X
has not
been replaced, this
indicates an
intermittent drive
failure. This message
also appears once
immediately following
drive replacement
whenever data must
be restored from
backup.
1780-Disk 0 Failure None Hard drive/format
error.
Run Diagnostics.
Replace failed
assembly as indicated
or contact your service
provider.
1781-Disk 1 Failure None Hard drive/format error Run Diagnostics.
Replace failed
assembly as indicated
or contact your service
provider.