Specifications
12 T
ROUBLESHOOTING
P
RESARIO
N
OTEBOOK
M
AINTENANCE
AND
S
ERVICE
G
UIDE
1400 S
ERIES
Presario 1400 Series
Models: XL240, XL241, XL242, XL244, XL245, XL246, XL247, XL250, XL340,
XL341, XL342, XL343, XL344, XL345, XL346, XL350, XL352, XL355, and XL356
Hard Drive Test Error Codes
Hard Drive Test Error Codes
Error Code Description Recommended Action
1701-xx Hard drive format test failed.
1. Run the Configuration and
Diagnostics Utilities and verify
drive type.
2. Ensure that all secondary
drives have secondary drive
capability.
3. Replace the hard drive and
retest.
4. Replace the system board and
retest.
1702-xx Hard drive read test failed.
1703-xx Hard drive read-write, compare
test failed.
1704-xx Hard drive random seek test
failed.
1705-xx Hard drive controller test failed.
1706-xx Hard drive ready test failed.
1707-xx Hard drive recalibration test
failed.
1708-xx Hard drive format bad track test
failed.
1709-xx Hard drive reset controller test
failed.
1710-xx Hard drive park head test failed.
1715-xx Hard drive head select test
failed.
1716-xx Hard drive conditional format
test failed.
1717-xx Hard drive ECC* test failed.
1719-xx Hard drive power mode test
failed.
1724-xx Network preparation test failed.
1736-xx Drive monitoring test failed.
*ECC = Error Correction Code