Installation Manual

TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL RLMC1005 SERIES
INS_RLMC1005_REV–
Rev. 27 Jun 2016 PAGE 4
INSTALLATION AND OPERATION MANUAL RLMC1005 SERIES
7 - VERIFY FUNCTIONALITY
See LED Indicator table below and Troubleshooting Guide if corrective action is needed.
Table 4 – Front Panel LED Indicators
Fiber Optic Link Fiber Optic Speed Fault Power
GREEN Solid Communication link has been established
over optical fiber. Flashes when data is
being transmitted.
1000 Mbps No Fault (NC-COM) Power Applied
Flashing Fiber failure or copper failure (Link Fault
Enable must be switched set to ON)
RED Solid 100 Mbps Fault (NO-COM)
OFF Communication link has not been
established.
Unit is not correctly
powered up
Unit is not correctly
powered up
Unit is not correctly
powered up
Figure 5Electrical Port
Ethernet
Speed
Ethernet
Link /
Activity
Installation Instructions (Continued)
Figure 6 - Fault Relay Operation
The fault relay is normally closed and will open on any of the following alarm conditions:
- Link Fault is enabled on the remote RLMC1005 unit and the corresponding copper port has been
disconnected.
- Link Fault is enabled on the local RLMC1005 unit and the corresponding copper port has been
disconnected.
- Fiber Fault is enabled on the local RLMC1005 unit and the fiber link is down or the power has been lost to
either the local or remote RLMC1005 unit.
Table 6 – Troubleshooting Guide
Problem Steps to Take
Power LED not lighting Check that power is properly applied to the unit using the correct connector pair.
No Communication Check Ethernet Link LEDs, Fiber Optic Link LEDs. Confirm Connections, and DIP switches are set properly.
Table 5 – Electrical Port LED Indicators
Link / Activity
Speed
GREEN Solid Communication link has been established over the electrical cable
Flashing Data is being transmitted over the electrical cable
OFF Communication link has not been established. 10/100 Mbps Speed