Installation Manual

INS_FVTFVR15M2_REV–
09/23/11
PAGE 3
TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL FVT/FVR15M2
FIGURE 4 – DATA CONNECTIONS
FIGURE 5 – DATA SETTINGS
RS-232/RS-422
TRANSMITTER RECEIVER
RS-232 OUT
GND
(+) DATA OUT
(-) DATA OUT
RS-422
4
3
2
1
O
O
O
Manchester/Bi-phase
GND
(+) DATA OUT
(-) DATA OUT
Manchester/
Bi-phase
4
3
2
1
O
O
(-) DATA IN
GND
(+) DATA IN
Manchester/
Bi-phase
3
2
1
O
O
RS-232/RS-422
Manchester/Bi-phase
(-) DATA IN
GND
(+) DATA IN
RS-422
RS-232
3
2
1
O
O
Customer
Equipment FVR15M2
Customer
EquipmentFVT15M2
RS-232
(+) DATA
GND
RS-232
GND
Data Transmit
Signal Ground
Data Receive
Signal Ground
RS-422
(+) DATA
(-) DATA
(+) DATA
(-) DATA
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
Bi-phase or
Manchester
(+) DATA
(-) DATA
(+) DATA
(-) DATA
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
FIGURE 6 – LED INDICATORS
VIDEO PRESENT TRANSMIT/RECEIVE DATA
GREEN Activity Activity
RED No Activity No Actvity
OFF Unit Powered Down