System information

70
SNTP Sever URL: Set the SNTP server IP address. You can assign a local network
time server IP address or an internet time server IP address.
Switch Timer: When the switch has successfully connected to the SNTP server
whose IP address was assigned in the column field of SNTP Server URL, the current
coordinated time is displayed here.
Daylight Saving Period: Set up the Daylight Saving beginning date/time and
Daylight Saving ending date/time. Please key in the value in the format of
‘YYYYMMDD’ and ‘HH:MM’ (leave a space between ‘YYYYMMDD’ and ‘HH:MM’).
YYYYMMDD: an eight-digit year/month/day specification.
HH:MM: a five-digit (including a colon mark) hour/minute specification.
For example, key in ‘20070701 02:00’ and ‘20071104 02:04’ in the two column fields
respectively to represent that DST begins at 2:00 a.m. on March 11, 2007 and ends
at 2:00 a.m. on November 4, 2007.
Daylight Saving Offset (mins): For non-US and European countries, specify the
amount of time for day light savings. Please key in the valid figure in the range of
minute between 0 and 720, which means you can set the offset up to 12 hours.
Click to have the configuration take effect.
SNTP Configuration interface