Installation Manual
Table Of Contents
- About This Guide
- Overview
- Hardware Overview
- Ethernet Cables
- WEB Management
- Configuration by Web Browser
- About Web-based Management
- Basic Setting
- System Information
- Admin & Password
- Auth Method
- IP Setting
- HTTPS
- SSH
- LLDP
- Backup/Restore Configuration
- Firmware Update
- DHCP Server
- Port Setting
- Port Trunk
- LACP
- Redundancy
- MSTP
- STP
- VLAN
- VLAN Setting Example
- SNMP
- Traffic Prioritization
- Multicast
- Security
- AAA
- RADIUS Overview
- Warning
- System Warning
- Monitor and Diag
- Port Statistic
- System Log Information
- Cable Diagnostics
- SFP Monitor
- Ping
- Syncronization-PTP
- PoE Configuration
- Status
- Factory Defaults
- System Reboot
- Configuration by Web Browser
- Command Line Interface Management
- Technical Specifications
INS_CWGE26FX2TX24MSPOE_REV– 5 Mar 2014 PAGE 50
INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE
TECH SUPPORT: 1.888.678.9427
How to use Unaware / C-Port / S-Port / S-Custom-Port
Port can be one of the following types: Unaware, C-port, S-port, and S-custom-port.
Ingress action Egress action
Unaware
The function
of Unaware
can be used
for 802.1QinQ
(double tag).
When the port received untagged frames, an
untagged frame obtain a tag (based on PVID) and is
forwarded.
When the port received tagged frames,
1. If the tagged frame with TPID=0x8100, it become a
double-tag frame, and is forwarded.
2. If the TPID of tagged frame is not 0x8100 (ex.
0x88A8), it will be discarded.
The TPID of frame transmitted
by Unaware port will be set to
0x8100.
The final status of the frame
after egressing are also effected
by Egress Rule.
C-port When the port received untagged frames, an
untagged frame obtain a tag (based on PVID) and is
forwarded.
When the port received tagged frames,
1. If a tagged frame with TPID=0x8100, it is
forwarded.
2. If the TPID of tagged frame is not 0x8100 (ex.
0x88A8), it will be discarded.
The TPID of frame transmitted
by C-port will be set to 0x8100.
S-port When the port received untagged frames, an
untagged frame obtain a tag (based on PVID) and is
forwarded.
When the port received tagged frames,
1. If a tagged frame with TPID=0x88A8, it is
forwarded.
2. If the TPID of tagged frame is not 0x88A8 (ex.
0x8100), it will be discarded.
The TPID of frame transmitted
by S-port will be set to 0x88A8.
S-custom-port When the port received untagged frames, an
untagged frame obtain a tag (based on PVID) and is
forwarded.
When the port received tagged frames,
1. If a tagged frame with TPID=0x88A8, it is
forwarded.
2. If the TPID of tagged frame is not 0x88A8 (ex.
0x8100), it will be discarded.
The TPID of frame transmitted
by S-custom-port will be set to
an self-customized value, which
can be set by the user using the
column of Ethertype for Custom
S-ports.