System information

INS_CNGE2FE8MSPOE+_REV–
12/20/12 PAGE 100
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+
TECH SUPPORT: 1.888.678.9427
event ComRing-topology-
change
[Systemlog|SMTP|Both]
G Set s ring topology changed event
type
switch(config)#event ring-topology-change
both
event systemlog
[Link-UP|Link-Down|Both]
I Set port event for system log switch(config)#interface fastethernet 3
switch(config-if)#event systemlog both
event smtp
[Link-UP|Link-Down|Both]
I Set port event for SMTP switch(config)#interface fastethernet 3
switch(config-if)#event smtp both
show event P Show event selection switch#show event
no event device-cold-start G Disable cold start event type switch(config)#no event device-cold-start
no event authentication-
failure
G Disable Authentication failure event
typ
switch(config)#no event authentication-
failure
no event ComRing-
topology-change
G Disable ComRing topology changed
event type
switch(config)#no event ring-topology-
change
no event systemlog I Disable port event for system log switch(config)#interface fastethernet 3
switch(config-if)#no event systemlog
no event smpt I Disable port event for SMTP switch(config)#interface fastethernet 3
switch(config-if)#no event smtp
show systemlog P Show system log client & server
information
switch#show systemlog