Specifications
INS_CNGE28FX4TX24MSPOE+_REV–
08/31/12 PAGE 79
INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE+
Tech SupporT: 1.888.678.9427
Static MAC Table Configuration
The static entries in the MAC table are shown in this table. The static MAC table can contain 64
entries.
The maximum of 64 entries is for the whole stack, and not per switch.
The MAC table is sorted first by VLAN ID and then by MAC address.
Label Description
Delete Check to delete the entry. It will be deleted during the next save.
VLAN ID The VLAN ID for the entry.
MAC Address The MAC address for the entry.
Port Members Checkmarks indicate which ports are members of the entry. Check or
uncheck as needed to modify the entry.
Adding a New
Static Entry
Select Add new static entry to add a new entry to the static MAC
table. Specify the VLAN ID, MAC address, and port members for the
new entry. Select Save.
Mirror
Configure port Mirror on this page.
To debug network problems, selected traffic can be copied, or mirrored, to a mirror port where a
frame analyzer can be attached to analyze the frame flow.
The traffic to be copied to the mirror port is selected as follows:
All frames received on a given port (also known as ingress or source Mirror).
All frames transmitted on a given port (also known as egress or destination Mirror).
Port to mirror also known as the mirror port. Frames from ports that have either source (RX) or
destination (TX) Mirror enabled are mirrored to this port. Disabled disables Mirror.