Specifications

INS_CNGE28FX4TX24MSPOE+_REV–
08/31/12 PAGE 65
INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE+
Tech SupporT: 1.888.678.9427
SNMP-Views
Configure SNMPv3 views table on this page. The entry index keys are View Name and OID
Subtree.
Label Description
Delete Check to delete the entry. It will be deleted during the next save.
View Name A string identifying the view name that this entry should belong to.
The allowed string length is 1 to 32, and the allowed content is the
ASCII characters from 33 to 126.
View Type Indicates the view type that this entry should belong to. Possible view
types are:
included: An optional flag to indicate that this view subtree should be
included.
excluded: An optional flag to indicate that this view subtree should be
excluded.
General, if a view entrys view type is ‘excluded’, it should be exist
another view entry which view type is ‘included’ and it’s OID subtree
overstep the ‘excluded’ view entry.
OID Subtree The OID defining the root of the subtree to add to the named view.
The allowed OID length is 1 to 128. The allowed string content is
digital number or asterisk(*).