Installation Instructions

CNGE2MC
10/100/1000 Mbps ETHERNET 2 PORT
MEDIA CONVERTER
GREEN
YELLOW
BLACK WITH WHITE STRIPE
BLACK
INS_CNGE2MC_REVA
04/07/09
Page 2
INSTALLATION INSTRUCTIONS
GREEN = Powered On
LINK A: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
RJ45
RJ45: YELLOW: Link = Highest Data Rate (1000 Mb/s)
GREEN: Solid = No Activity
Blinking = Activity
Off = No Link
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should be installed in a restricted access location; available through the use of a lock and key or other
means of secur
ity. Access should be limited to service personnel who have been instructed about the reasons for the restrictions
to the location. Any and all precautions should be taken and controlled by the authority responsible for the location.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly,
the op
erating ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installa
tion of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.