Operating Instructions and Installation Instructions
ComNav Navigator G2 Installation & Operation Appendices
Document PN 29010081 V1.1 - 51 -
Appendix 3
Wiring Termination in the Distribution Unit
This section describes the best practices to terminate and connect the wiring harnesses into
the Navigator Distribution Unit Two-Tier Terminal Strips. You may choose to do this if you
shorten a wire harness to the length required on your vessel. Tools you will need include:
• Jacket Insulation Strippers,
• Wire Strippers for 22, 20, and 18 Gauge Wires,
• Small slotted screwdriver, and
• Wrenches to tighten Cord Grips
Wires and wire harnesses into the Distribution Unit should be prepared with approximately
12cm (5 inches) of wire pig tails, and between 5mm (1/4 inch) to 9mm (3/8 inch) of bare wire
exposed. Figure 26 to Figure 28 illustrates the recommended cable and wire preparation.
Figure 26 - Cable Jacket Removal
www.busse-yachtshop.de | info@busse-yachtshop.de