13
5. Complete all configurations and click Apply Settings to save settings. Exit and
restart the receiver to activate configurations.
4.2 Static Data Collection
Static survey is mainly used for the control survey. To reach millimeter accuracy,
follow as below:
At least 3 GNSS receivers are required to form a stable triangulation network.
It is better to set Data Log Session as manual on the known point.
Power off the receiver before moving to other observation site.
To quickly post-process static observation raw data, write down the station
name, receiver SN, antenna height, start and end time for each observation
site.
Tip: You can start recording static data in the front panel, it’s convenient for you.
4.3 Static Data Download
The raw observation data is saved in internal memory of N5 receiver, when
connected with PC via USB cable, the N5 receiver can work as a USB Flash Disk,
which means you can copy or cut static data to PC directly.