Hardware manual

23
STAC5 Hardware manual
920-0026 Rev. C
9/4/2014
Connecting an NPN Type Proximity Sensor to an input
(When prox sensor activates, input goes low).
IN/OUT2
NPN
Proximity
Sensor
IN3..IN6
INCOM
output
+
12-24
VDC
Power
Supply
-
+
Connecting a PNP Type Proximity Sensor to a an input
(When prox sensor activates, input goes low).
IN/OUT2
PNP
Proximity
Sensor
IN3..IN6
output
+
INCOM
12-24
VDC
Power
Supply
-
+
Connecting a Potentiometer to the Analog Input
Analog Input
The STAC5 drives feature one analog input. It can accept a signal range of 0 to 5 VDC, ±5 VDC,
0 to 10 VDC or ±10 VDC. The drive can be congured to operate at a speed or position that is
proportional to the analog signal.
Use the STAC Configurator software to set the signal range, offset, deadband and filter fre-
quency.
1-10k
pot
cw
ccw
IN/OUT 1
GND
AIN
+5V OUT
8
15
7
inside drive
+5V OUT
AIN
GND
8
15
7
DB-15 Connector
Signal
Conditioning