Hardware manual

12
STAC5 Hardware manual
920-0026 Rev. C
9/4/2014
Connecting AC Power
Using the connector supplied connect to the AC supply per the diagram below. Use 16 AWG wire for Line (L) and Neutral (N). Use 14
AWG for Earth Ground ( ).
Care should always be taken when working with high voltages.
In regions where the single-phase supply is higher, an auto transformer can be used to drop the voltage to the correct level.
Fusing
The STAC5-120 contains an internal 8A fast acting fuse. The STAC5-220 contains an internal 3.5A fast acting fuse. If an external fuse is
desired, we recommend a 6A fast acting fuse for the 120V STAC5 and a 3 amp fast acting fuse for the 220V version.
Line Filter
For applications requiring CE EMC compliance, a Corcom 6ET1 line filter is required in series with the AC input.
To Line (Hot)
To Neutral
To Earth Ground
FUSE
LINE FILTER
SURGE PROTECTOR