User Manual

Electrical Specification : Up-Link Down-Link
Model CE-1819-AD A&D Block: 1850-1870 MHz 1930-1950MHz
Model CE-1819-B B Block: 1870-1885 MHz 1950-1965MHz
Model CE-1819-C C Block: 1895-1910 MHz 1975-1990MHz
Downlink:
System Gain 3 to 8 dB
Gain Flatness ± 0.5 dB Max
Operating Output Power/Single Carrier
(meeting ACPL CDMA requirements) 20 Watts Max
Output Third Order Intercept Point: +50 dBm Typ
Input/Output VSWR 1.5:1 Max
Uplink:
System Gain 4 to 12 dB
Gain Flatness ± 0.5 dB Max
Noise Figure: 2.5 dB Max.
Output Third Order Intercept Point: +30 dBm Min.
Input/Output VSWR 1.5:1 Max
Up-link/Down-link Isolation 80 dB Min
By-Pass Insertion Loss 0.5 dB
Operating Voltage: 115/220VAC or 28VDC
Current Consumption: 3 A @ 120VAC
Alarms
One common alarm is standard
Mechanical Specifications :
Dimensions: 14”x 8”x 7”
Enclosure: NEMA 4X Aluminum Die-cast
Connectors: “ N” or 7/16 DIN
Weight: 20 Lbs. Max.
Mounting: Mounting Studs