User's Manual

* With External Tower Mounted Amplifier
* Reverse Link Forward Link
PCS Operating Range 1850-1910MHz 1930-1990 MHz
Nominal 20 dB Bandwidth 60 MHz 39.27 MHz
PCS band specific filters AD, BE, FC AD, BE, FC
Nominal Pass-Band Gain 12 dB max Adjustable to 13.94 dB max
System Noise Figure: 1.5.0 dB Max.
System Group Delay: 180 nanosecond Max
Pass Band Ripple: +/-0.5 dB Max.
Output Third Order IM3 @
1.98 MHz 0ffset:
-55 dBc/30 kHz
1 dB Compression Point: +15 dBm Min. +58.5 dBm Typ.
Input /Output VSWR: 1.5:1 Max. 1.5:1 Max.
Up-Link-Down-Link Isolation 80 dB
By-Pass Insertion Loss 0.5 dB for ground level unit, 0.3 dB for tower top
unit
Nominal Mean Output
Power:
125 W ; 63 W for Canada
Input and Output Impedance 50 Ohm
Power Supply Voltage: 220 VAC
Power Consumption: 1.0 KW Max per sector
Dimensions 12”L x 5.5” W x 3”D -tower unit
77”H x 24”W x 21”D - ground level unit
Enclosure NEMA 3R Weather Proof Cabinet
Connectors Input from BTS –type N, F; output to hard lines -7
/16 DIN, F; TTA—7/16 DIN, F
Weight TTA –10 Lbs, GLU –100 Lbs for one sector
Mounting TTA –antenna pipe, GLU - concrete pad, 2.5’x2.5’
area
Operating Temperature: -25° to +50° C Ambient