<Field Name="Stepper Current Limit" Value="310" />
<Field Name="Current Sample Duty Cycle" Value="35" />
<Field Name="Stepper Pulse Frequency" Value="500" />
<Field Name="Lower Position" Value="369" />
<Field Name="Center Position" Value="537" />
<Field Name="Present Sweep Count" Value="0" />
<Field Name="Upper Position" Value="706" />
<
Field Name="Present Mechanical Position" Value="706" />
<Field Name="Mechanical Span" Value="101.4" />
<Field Name="Temperature (deg C)" Value="29.0" />
<Field Name="Minimum Temperature (deg C)" Value="23.4" />
<Field Name="Maximum Temperature (deg C)" Value="29.0" />
<Field Name="Motor Voltage (V)" Value="29.938" />
<Field Name="Minimum Motor Voltage (V)" Value="15.392" />
<Field Name
="Maximum Motor Voltage (V)" Value="29.938" />
<Field Name="3.3V Logic Voltage" Value="3.328" />
<Field Name="3.3V Minimum Logic Voltage" Value="3.324" />
<Field Name="3.3V Maximum Logic Voltage" Value="3.333" />
</Settings>
</Antenna>
Figure 3. Site Report File Viewed Using Internet Browser.
For the following Andrew Antennas, Andrew recommends no more than 130 meters of total
data cabling to the last actuator.
MB72RR80VDPALQ_R12 MB72RR65VDPALQ_R12
MB48RR80VDPALQ_R12 MB48RR65VDPALQ_R12
RR6518VDPL2_R RR9017VDPL2_R
RR6518VDUL2_R RR3320VDPL4_R
RR6513VDBL2-R RR9012VDBL2-R
Multiple homerun cables can be used for very demanding installations. Note that for 15 inch
COBRA actuators, Andrew recommends a homerun cable be used for each sector with a
maximum of 3 antennas on a sector.