Specifications
Appendix D Field Replaceable Units
ONECELL
®
Hardware Installation, Release 4.5 D-3
D
R
A
F
T
Off-site activities
Before replacing the BC module, import a new EDF file to the DMS. This file
contains the BC MAC address and HeMs password specific to the new BC.
1 Access the FTP location on DMS using ftp protocol, port 2100.
2 Upload the EDF file to /appdata/dms/import/factory.
3 Access the DMS Network console from a supported Web Browser.
NOTE: The DMS GUI supports Microsoft Edge 81 and later, Google Chrome 81
and later, and Mozilla Firefox Quantum 68 and later.
4 Enter the IP address for the Network Management portal.
http://<IP Address DMS server>/networkconsole
The Sign In dialog box displays.
5 Enter Username and Password. The Search Device screen displays.
7 Configuration details for WebGUI commissioning
Note: These parameters are derived from the failed
unit being replaced.
8 Ethernet cable
Note: Required for connecting the laptop to the
ONECELL Baseband Controller Management port
9 DMS FTP IP address
Step Prerequisite Completed