Users Manual Part 2

Appendix C Specifications
C-2 M0303A2 4.5.01 September 2020
D
R
A
F
T
Environmental and physical specifications
The following table lists the electrical ratings and technical data for the Baseband
Controller, RP5100 series and RP2000/RP2100.
Table C-1. Environmental and Physical specifications
Baseband Controller
Environmental Operating Temperatures: 0°C to 40°C
Operating Humidity 10%-90% Non-Condensing
Power Requirements 120/230 VAC,1.7/0.85 A, 50/60 Hz
Power Consumption 204W Typical / 216W Maximum
Dimensions 1 Rack Unit Chassis hosts 2 Baseband Controller module units
19" W x 1.75" H x 18.8" D (483mm W x 44.4mm H x 477mm D)
Weight Single BC 13.1 lbs (5.9 kg)
Dual BC 19.1 lbs. (8.7 kg)
RP5100i
Environmental Operating Temperatures: 0 to 50°C (Plenum rated: UL-2043)
Operating Humidity 10%-95% Non-Condensing
Operating temperatures: 0°C to 50°C
Active Cooling/Fans, acoustic noise: 39.5 dBA at 25C
Power Requirements IEEE802.3bt-type 4 PoE++
Power Consumption Up to: 72W (26W + 11.5W per RM)
Dimensions 13.54" W x13.54 H x 3.35" D
(344.0 mm W x 344.0 mm H x 85.0 mm D)
Weight 8.82 lbs (4 kg)
RP5100r
Environmental Operating Temperatures: 0 to 50°C (Plenum rated: UL-2043)
Operating Humidity 10%-95% Non-Condensing
Operating temperatures: 0°C to 50°C
Active Cooling/Fans, acoustic noise: 39.5 dBA at 25C
Power Requirements IEEE802.3bt-type4 PoE++
Power Consumption Up to: 72W (26W + 11.5W per RM)
Dimensions 14.9" W x 12.64" H x 4.06" D
(378.7 mm W x 321.1 mm H x 102.5 mm D)