Degrees of Latitude Value (N) is derived by the formula:
N <223 X / 90 < N + 1
where X is the latitude in degrees (0
o
..90
o
)
Type: INTEGER (0..223 - 1)
Degrees of Longitude Value (N) is derived by the formula:
N <224 X / 360 < N + 1
were X is the longitude in degrees (-180
o
.. +180
o
)
Type: INTEGER (-223 .. 223)
Altitude Info
Degrees of Altitude • height
•depth
Altitude The relationship between the value (N) and the altitude (a) in
meters it describes as N < a < N+1, except for N=215-1, for which
the range is extended to include all greater values of (a).
Type: INTEGER (0..215 - 1)
Uncertainty Altitude Uncertainty altitude “h” expressed in meters, is derived from the
“Uncertainty Altitude” k, by:
h=45 x (1.025k - 1)
Type: INTEGER (0..127)
Position Estimate
Uncertainty Semi-Major Uncertainty “r” is derived from the “uncertainty code” k by:
r = 10 x (1.1k - 1)
Type: INTEGER (0..127)
Uncertainty Semi-Minor Uncertainty “r” is derived from the “uncertainty code” k by:
r = 10 x (1.1k - 1)
Type: INTEGER (0..127)
Orientation of MajorAxis Type: INTEGER (0..179)
Confidence Percentage of confidence
Type: INTEGER (0..100)
SNMP Configuration
SNMP Traps •True
•False
If true, SNMP traps will be generated from OneCell devices
SNMP IP address/Domain
Name
The IP address or FQDN of the SNMP management server
Table 5-2. Baseband Controller operator parameters, configuration file
Parameter Description