Table 5-2. Baseband Controller operator parameters, configuration file
Parameter Description
Network Topology
Number of IPSec Tunnels Number of IPSec Tunnels to be used by the Baseband Controller
none – If Tunnel mode is Non IPSec
one – If Tunnel mode is Single IPSec Tunnel
two – If Tunnel mode is Dual IPSec Tunnel
EPC Traffic Mode Tunnel Mode for EPC Communication
ipsecTunnel1 – Single IPSec Mode
nonIPSec – Non IPSec Mode
HeMS Traffic Mode Tunnel Mode for EPC Communication
ipsecTunnel1 – Single IPSec Mode
ipsecTunnel2 – Dual IPSec Mode
nonIPSec – Non IPSec Mode
CA Traffic Mode Tunnel Mode for EPC Communication
ipsecTunnel1 - Single IPSec Mode
ipsecTunnel2 - Dual IPSec Mode
nonIPSec - Non IPSec Mode
noCA - No CA Mode
Timing Source
GPS Timing Source is GPS
Boundary Clock Interface Port boundaryClock – Timing Source is PTP with a dedicated
Boundary Clock port configured
backHaul – Timing Source is PTP with no dedicated Boundary
Clock port configured
Redundancy True – BC Redundancy Enabled
False – BC Redundancy Disabled (Standalone)
Network Interface Port Configurations – Management Interface
IP Address Assignment Static mode – IP Addresses are configured manually.
DHCP (Client) mode – The DHCP client fetches IP addresses
from the DHCP server and assigns them to the interface. User
configuration is not required.
IP Address IP Address of the interface
<A.B.C.D>