User Manual
Table Of Contents
- Contents
- List of figures
- List of tables
- About this document
- ipBTS system overview
- Planning
- ipBTS C30 installation
- RN commissioning
- Requirements
- CLI connection
- Establishing a console connection
- Connecting the laptop to the ipBTS C30
- Downloading and activating new software
- Verifying SNTP time
- Commissioning the ipBTS C30
- Performing Loopback tests
- The loopback test process
- Backhaul loopback testing
- Ethernet loopbacks
- Looping back Ethernet backhaul links
- Looping back at the Ethernet port
- Entering diagnostic mode and configuring test parameters
- Performing external loopback tests on backhaul links
- Troubleshooting failed backhaul links
- Removing physical loopbacks
- Configuring IP on the Ethernet port and laptop
- Establishing the CLI/SSH/Ethernet connection
- Updating node software
- RN hardware components
- RN Specifications
- Hot-swapping ipBTS hardware
- Index
Chapter 4 l RN commissioning
Configuring IP on the Ethernet port and laptop
4-20 910136 Rev01.00 Standard July 2007
2. Boot up the laptop.
3. Retrieve the CLI cable.
4. Check the ACTIVE LED to determine if the ADCC module is active
5. Connect the male DB-9 end of the serial cable to the female DB-9 port on the active
ADCC module.
6. Connect the other end of the serial cable to the COM port of the laptop.
7. Launch the terminal emulation program.
You can use HyperTerminal, which comes with windows, or any terminal emulation
program of your choice.
8. Open a terminal connection as appropriate for the terminal emulation software.
9. Set the terminal connection parameters to those shown in Table 4-7.
NOTE: If you are establishing CLI/serial connection the serial ports on the RM or TFU
modules, you must set the Bits per second to 115200.
10. Press
<ENTER> on the laptop.
The CLI command prompt displays as follows:
ipBts-XXX>
Configuring IP on the Ethernet port and laptop
This procedure explains how to configure IP addressing so that you can use SFTP to transfer a
new release from the laptop Ethernet port to the node over the ADCC Ethernet port.
This procedure requires an active CLI/serial connection to the ADCC.
Table 4-7. Terminal settings for CLI/serial connection
Setting Value
Terminal emulation type VT220 or VT100
Bits per second (BAUD) 38400
Data bits 8
Parity None
Stop bits 1