User Manual

Table Of Contents
Chapter 4 l RN commissioning
Establishing a console connection
4-6 910136 Rev01.00 Standard July 2007
NOTE
The Ethernet port IP addresses are necessary only if you are downloading software using an
Ethernet connection, which is recommended. For more information, contact your network
planner.
Table 4-3. Configuration parameters
Object Parameter Description
Interfaces ifAdminStatus The desired state of the interface: up (1), down (2), or testing (3).
Note: The testing (3) state indicates that no operational packets can be passed.
The address at the protocol layer immediately “below” the network layer in the
protocol stack.
Note: For interfaces that do not have such an address, for example, a serial
connection, the ifPhysAddress has a length of zero (0).
ifPhysAddress
SectorElements TimingAdvance The timing advance for the SectorElement. Range {0..255} with default 0.
ControlChannelRate The data rate of the Control Channel of the SectorElement. Range: unknown (1),
38.4 Kbps (5), 76.8 Kbps (6) with default value unknown (1).
PNOffset The pn offset for the SectorElement. Range: {0..511} with a default (0).
CountryCode The country code with which the SectorElement is associated. Range: {0..255}
with a default (0).
SubnetMaskLength The length of the subnet mask used to extract the subnet from the sector ID.
Range: {0..127} with a default (0).
RouteUpdateRadius The distance measured between the serving sector and the sector that triggered a
new route update. Range: {0..2047} with a default (0).
SectorIndex The sector index number of the sector. Range {1..65535}.
CarrierIndex The index of the carrier object to which this SectorElement is bound. Range:
{1..65535}
Note: The value of this attribute can be changed only when the status of this
SectorElement object is down (1).
AdminStatus The administrative status for the SectorElement. Range: down (1), up (2),upTest
(3)