User Manual

Chapter 1 Introducing the IP-Radio Node 8000
22 Release 2.0, 910056 Rev01d
Understanding the Base Input Output/System Controller module
The Base Input Output/System Controller (BIO/SC) provides backhaul support, system control services, and
timing distribution to internal IP-RN 8000 components. See Figure 12
and Table 13.
The primary BIO/SC installs in slot 3. The optional redundant BIO/SC installs in slot 7.
The BIO/SC is field-replaceable and hot swappable. Hot swapping a BIO/SC is service disrupting if it is the
active BIO/SC in a redundant configuration. Therefore switching service to the standby BIO/SC in
redundant systems before replacing the module is recommended.
For information about installing the BIO/SC module:
See Understanding the installation process
on page 40.
See Understanding the module installation process
on page 104.
Table 12 TFU faceplate components
Component Description
Latches and screws Top and bottom latches Close to insert the TFU in its slot.
Open to remove the TFU from its slot.
Captive screw(s) Tighten to secure the TFU in its slot.
Loosen before removing the TFU from its slot.
LEDs Power Lights green when the TFU receives power.
Alarm Lights red when the TFU is in an alarm state.
Standby Lights amber when the TFU is in standby mode in a
redundant configuration.
Active Lights green when the TFU is in active mode in a redundant
configuration.
10 MHz Out This is a 10 MHz sample port for connecting external test equipment.
Connector type: BNC.