Installation Guide
10
Operation (continued)
Option 2: Switch controlled
Switch controlled operation enables the light xture to turn ON and
OFF by ipping a switch that controls the electricity to the outlet
powering the xture. The light xture will not turn ON and OFF
automatically, but is manually controlled.
□ To enable switch activated operation leave the black cap
cover (F) on the photocell (E).
F
E
Care and Cleaning
□ Shut off the main power supply before cleaning the product. To prolong the original appearance, clean the light xture with clear water
and a soft, damp cloth only.
□ Do not use abrasive cleaners or cleaners that contain alcohol. Do not apply paints, solvents, or any other chemicals on this light xture.
They could cause a premature deterioration of the nish and may void the warranty.
□ Do not spray the light xture with a hose or power washer.
Troubleshooting
Problem Possible Cause Solution
The light does not turn
ON.
There is no power to the
xture.
□ Check if circuit breaker is tripped.
□ Conrm wall switch is ON. Verify wiring to the xture is correct (turn power
OFF to xture beforehand).
The xture senses daylight. Cover the photocell. Wait several seconds until the xture turns ON.
The light cycles ON
and OFF continuously.
The photocell light sensor is
sensing reected light.
□ Relocate the light xture to a location where there is no reected light.
□ OR place the optional photocell cover over the photocell light sensor and use
the wall switch to turn the light ON and OFF.
The light ickers.
The light xture is wired
through a dimmer switch.
Do not use a dimmer switch to control the light xture. Replace the dimmer with a
standard ON/OFF switch.
The light stays ON.
The light sensor is in a
shaded area.
□ Shine a ashlight into the light sensor and wait up to a minute. If the light
turns OFF, the xture should be moved to a location with enough light in the
daylight hours for the light sensor to work.
□ OR place the optional black cover over the photocell light sensor and use the
wall switch to turn the light ON and OFF.
The light sensor is faulty.
If the light does not turn OFF when a ashlight is shined on the light sensor for a
few minutes, then the sensor may be faulty. Please contact customer service.
NOTE: Photocell (E) has a short delay in order to reduce its sensitivity to sudden light changes. When testing, shine a light and cover
the photocell for up to a minute to check if the xture functions properly.