Installation Guide

3
LIGHT DISTRIBUTION
End cap
Max:110°
Mounting Height: 10ft.
Detection Range: Max 13ft.
disable 10min 2min
C
D
CONTINUOUS INSTALLATION
Multiple light fixtures can be connected, up to a maximum of seven 40 in. shop lights or 266 total watts. Only the first light
fixture needs to be plugged into an electrical outlet.
1. Remove the end cap from one end of each fixture body that will be linked.
2. Connect each additional fixture using either the linking cable (C) or end-to-end connector (D). When using the linking cable,
the maximum distance between two light fixtures is 5 ft.
3. For best results, fully insert the linking cable (C) or end-to-end connector (D) into the receptacle in the end of the shop light.
WARNING: RISK OF ELECTRIC SHOCK. Disconnect power to the shop light before linking additional shop lights. Do not
touch live parts inside the receptacle.
ADJUSTING THE HOLD TIME OF MOTION SENSOR
1. This shop light allows you to customize the hold time of the motion sensor
using 3 settings: 2min, 10min, Disable.
2. Move the switch on one end cap of the fixture to make your selection before
activating the fixture.
NOTE: Detects Motion up to 13 ft. Away at mounting height of 10 ft.
The maximum sensing angle is 110°. And the motion sensor should
be mounted in the down position. The detection distance is measured
based on human beings’ movement towards circular tangent direction.
574
287
861
Maximum Candela = 1148.302
Located At Horizontal Angle = 0, Vertical Angle = 0
# 1 - Vertical Plane Through Horizontal Angles (0-180)
# 2 - Vertical Plane Through Horizontal Angles (90-270)
1148
1
2