ENGLISH CONTENTS SAFETY INFORMATION Important Safety Instructions...........................................................................................................................................................4 Battery Information............................................................................................................................................................5 Grounding Instructions..........................................................................................
ENGLISH SAFETY INFORMATION DANGER DANGER - Immediate hazards which WILL result in severe personal injury or death WARNING WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death CAUTION CAUTION - Hazards or unsafe practices which COULD result in minor personal injury IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions should be followed, including the following 1.
ENGLISH SAFETY INFORMATION 14. Children should be supervised to ensure that they do not play with the appliance. SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY BATTERY INFORMATION KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to serious injury or death. Severe burns can occur within 2 hours of ingestion. Immediately see a doctor and have the doctor phone (202) 625- 3333 collect. Keep in original package until ready to use. Dispose of used batteries immediately.
ENGLISH SAFETY INFORMATION GROUNDING INSTRUCTIONS ELECTRICAL REQUIREMENTS The electrical requirements are a 115 volt 60 Hz, AC only, 15 amp. It is recommended that a separate circuit serving only the product be provided. The product is equipped with a 3-wire cord having a 3-prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded. This appliance must be grounded.
ENGLISH SAFETY INFORMATION POWER CORD USE The power supply cord contains a current device that senses damage to the power cord. To test your supply cord follow these steps: 1. Plug in the Air Conditioner. 2. The power supply cord head has two buttons, a TEST button and a RESET button. Press the TEST button and notice a click as the RESET button pops out. 3. Press the RESET button. Once again notice a click as the button engages. 4. The power supply cord will now supply electricity to the unit.
ENGLISH SAFETY INFORMATION SAFETY GUIDELINES To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. ALWAYS DO THIS NEVER DO THIS •Y our air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid.
ENGLISH SET UP & USE NOTE: A ll the illustrations in this manual are for explanation purpose only. The air conditioner you have may be slightly different. WINDOW REQUIREMENTS: H Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584mm to 914mm) . MODEL: 10,000~12,000 BTU - HEIGHT: 15-1/2 (394mm) H H CAUTION • Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
ENGLISH SET UP & USE PREPARE THE WINDOW Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (330mm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
ing ng ndow sash al foam (1) re e ripping are 12 ) re 00 0 els els dware dels dels ENGLISH w sash sash am am SET UP & USE C: A lign the hole in the top rail with those in the top of the unit as shown in Fig. B Fig. B B. Slide the free end “I“ section of the panel directly into the cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. Fig.
ENGLISH Top right Top right SET UP & USE SECURE THE ACCORDION PANELS A. Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig. 5A and Fig. 5B). Carefully close the window behind the top rail of the unit. Fig.
ENGLISH SET UP & USE INSTALL R1 HARDWARE INSTALL WEATHER STRIPPING In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R1 hardware to the side curtain. Follow the instructions below. (only be applicable to Energy star models) Step 1. A fter the unit is installed to the window, measure the inner width of the side curtain as shown (Fig.11). Step 2.
ENGLISH SET UP & USE AIR CONDITIONER FEATURES WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. CAUTION: Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan and back to cool. This prevents compressor from overheating & possible circuit breaker tripping. To begin operating the air conditioner, follow these steps: 1.
ENGLISH SET UP & USE PARTS & FEATURES Horizontal Louvers Remote Control MODE TIMER SPEED ENERGY SAVER ONE TOUCH SLEEP Control Panel MODE TIMER SPEED ENERGY SAVER ONE TOUCH SLEEP Filter Control Panel BATTERY INSTRUCTIONS Lock sign Coin Lock sign Unlock sign Battery cover Coin LockUnlock sign sign Groove Note: Battery Not Included Lock sign Coin Groove Battery cover Coin Unlock sign Battery cover Step 1: I nsert a coin vertically in the groove on the battery Unlock sign Groove Groove Battery
ENGLISH SET UP & USE REMOTE CONTROL Power Button Mode Button MODE Temp Down - Temp Up + Timer button Speed Button Energy Saver One Touch TIMER SPEED ENERGY SAVER ONE TOUCH Sleep Button SLEEP POWER BUTTON Operation starts when this button is pressed and stops when the button is pressed again. NOTE: If the unit has ENERGY SAVER function, it will initiate automatically the Energy Saver function under Cool, Dry, and Auto (only AutoCooling and Auto-Fan) modes.
ENGLISH SET UP & USE OPERATING INSTRUCTIONS The unit can be controlled by the unit control alone or with the remote. NOTE: The outline of the operation panel is based on typical model, the function is the same with your air conditioner while some difference may exist in appearance. TO TURN UNIT ON OR OFF: Press ON/OFF button to turn unit on or off. NOTE: T he unit will initiate automatically the Energy Saver function under Cool, Dry and Auto modes.
ENGLISH SET UP & USE TO OPERATE ON AUTO FEATURE: • W hen you set the air conditioner in AUTO mode, it will automatically select cooling, heating (cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature. • T he air conditioner will control room temperature automatically round the temperature point set by you. • I n this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature.
ENGLISH CLEANING & CARE DANGER 1. Be sure to unplug the unit before cleaning or servicing. 2. Do not use gasoline, thinner or other chemicals to clean the unit. CABINET CLEANING • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. 3.
ENGLISH TROUBLESHOOTING & WARRANTY BEFORE YOU CALL FOR SERVICE IF THE AIR CONDITIONER FAILS TO OPERATE: A) Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again securely. B) Check for a blown circuit fuse or a tripped main circuit breaker. If these seem to be operating properly, test the outlet with another appliance. IF NONE OF THE ABOVE SOLVES THE PROBLEM, CONTACT A QUALIFIED TECHNICIAN.
ENGLISH TROUBLESHOOTING & WARRANTY TROUBLE ANALYSIS Air conditioner does not start • Wall plug disconnected. Push plug firmly into wall outlet. • House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. • Plug Current Device Tripped. Press the RESET button. • Power is OFF. Turn power ON. Air from unit does not feel cold enough •R oom temperature below 62˚F (17˚C). Cooling may not occur until room temperature rises above 62˚F (17˚C).
ENGLISH TROUBLESHOOTING & WARRANTY LIMITED WARRANTY Any repair, replacement, or warranty service, and all questions about this product should be directed to W Appliance Co. at 1 (855) 855-0294 from the USA or Puerto Rico. W Appliance Co. warrants to the original purchaser that the product will be free from defects in material, parts and workmanship for the period designated for this product.