Specifications

- 35 -
5.3.7 Automatic Input Signal ON Selection Parameter Configuration
Configure the input signal automatic ON selection parameter.
The parameter “PD01Input signal automatic ON selection” settings, defines which input signals will turn ON
automatically when the control circuit power supplyis turned on., doing this allows additional I/O signal
selection range.
Please allocate it according to your system specification.
Configure the automatic ON selection in parameter [PD01], or configure the I/O signal layout. If I/O signal
wiring layout is altered, do not configure PD01Input signal automatic ON selection.
*If all I/O signals are controlled, please set PD01 to 0000.
Please configure PD01Input signal automatic ON selection in Hexadecimal (HEX).
During Actuator Operation: <Signals which must be ON during actuator operation>
Set PD01 as 0C24. The following signals will automatically turn on when power supply turns on.
SON Servo-on
OFFServo-off
ON Servo-on (operational)
LSP Forward rotaion Stroke end
(normally closed contact)
OFF Forward rotaion Stroke end
ON Forward rotaion Stroke end off (operational)
LSN Reverse rotaion Stroke end
(normally closed contact)
OFFReverse rotaion Stroke end
ON Reverse rotaion Stroke end off (operational)
EM1 Forced stop
(normally closed contact)
OFFForced stop
ON Forced stop off (operational)
In positioning mode (point table), congifure the operation mode using automatic/manual selection MD0.
The MD0 off selection will allow Jog operation and it will require an input reserved for MD0.
For Automatic MD0 please set PD01 as 0C25. Will also include MD0 automatic ON.
MD0 Automatic/manual selection ON: Automatic Operation Mode
Home position return/positioning mode operation available.