Specifications

- 31 -
LEY63 LEY63D
Lead symbol A B C L A B C
Series
Lead 20 10 5 2.86 20 10 5
Parameter Para. No
Initial
value
Recommended value
Number of command
input pulses per
revolution
*3.
PA05
100
100
Electronic gear
numerator *3.
PA06
1
100
(10)
35
(7)
100
(10)
Electronic gear
denominator *3.
PA07
1
20
10
5
1
(2)
20
10
5
Feel length
multiplication (STM)
(Multiplier)
PE02
0000
0000 (<1000 stroke)/0001 (>1000 stroke)
Home position return
type
PE03
0010
□□□3 (Stopper type)
Home position return
direction
PE03
0010
□□1 (Motor side)
Home position return
Speed (rpm)
PE04
500 30 60 120 210 30 60 120
Home position
return/JOG operation
Accelerationeration/D
eceleration time
constants (msec)
PE07 100 1000 500 250 143 1000 500 250
Home position return
position data (μm)
PE08 0 -4000 (<1000 stroke)/-400 (>1000 stroke)
Stopper type home
position return
stopper time (msec)
PE10
100 200
Stopper type home
position return torque
limit value (%)
PE11 15 30
Regenerative option PA02 000 000 (Non)/002 (LEC-MR-RB-032)/003 (LEC-MR-RB-12)
Rotation direction
selection
PA14 0
0
(
+Counter motors side
)
1
(+Counter motors side )
Adaptive tuning
mode
PB01 000 000
Load to motor inertia
moment ratio
PB06
7 7
Machine resonance
suppression filter 1
PB13
4500 4500
Notch shape
selection 1
PB14
000 000
Differs to initial value
*1. Parameter is set to the recommended value. Please set parameter according to customer application.
*2. Mechanical resonance may occur depending on the shape or mounting orientation of the work piece. Please
change this parameter during initial configuration.
(Parameter initial configuration Set the recommended parameter value Operation start)
*3. Other than positioning mode: Actuator travel distance at 10 [μm/pulse] per pulse.