Specifications
- 31 -
LEY63 LEY63D
Lead symbol A B C L A B C
Series
Lead 20 10 5 2.86 20 10 5
Parameter Para. No
Initial
value
Recommended value
Number of command
input pulses per
revolution
*3.
PA05
100
100
Electronic gear
numerator *3.
PA06
1
100
(10)
35
(7)
100
(10)
Electronic gear
denominator *3.
PA07
1
20
10
5
1
(2)
20
10
5
Feel length
multiplication (STM)
(Multiplier)
PE02
0000
0000 (<1000 stroke)/0001 (>1000 stroke)
Home position return
type
PE03
0010
□□□3 (Stopper type)
Home position return
direction
PE03
0010
□□1□ (Motor side)
Home position return
Speed (rpm)
PE04
500 30 60 120 210 30 60 120
Home position
return/JOG operation
Accelerationeration/D
eceleration time
constants (msec)
PE07 100 1000 500 250 143 1000 500 250
Home position return
position data (μm)
PE08 0 -4000 (<1000 stroke)/-400 (>1000 stroke)
Stopper type home
position return
stopper time (msec)
PE10
100 200
Stopper type home
position return torque
limit value (%)
PE11 15 30
Regenerative option PA02 000 000 (Non)/002 (LEC-MR-RB-032)/003 (LEC-MR-RB-12)
Rotation direction
selection
PA14 0
0
(
+:Counter motors side
)
1
(+:Counter motors side )
Adaptive tuning
mode
PB01 000 000
Load to motor inertia
moment ratio
PB06
7 7
Machine resonance
suppression filter 1
PB13
4500 4500
Notch shape
selection 1
PB14
000 000
Differs to initial value
*1. Parameter is set to the recommended value. Please set parameter according to customer application.
*2. Mechanical resonance may occur depending on the shape or mounting orientation of the work piece. Please
change this parameter during initial configuration.
(Parameter initial configuration ⇒ Set the recommended parameter value ⇒ Operation start)
*3. Other than positioning mode: Actuator travel distance at 10 [μm/pulse] per pulse.