Owner`s manual

177
Programming Option Default setting Alternate setting
Reversal on Idle Off on
CND Detection CND not set CND set
Dialtone detection Off On
Programming CND Detection
On standard PSTN lines on the Commander Pulse the CND
option is provided. The system can then detect when CND
information is being sent from the network and display the
number.
1. From the Programming Station, press the PROGRAM Key
2. Press the Scroll Down Key (Ô) until ‘System programming’
is displayed.
3. Select ‘System programming’.
4. Enter the System Programming Password and select
‘Lines’.
5. Press the Scroll Down Key (Ô) until ‘PSTN programming’ is
displayed.
6. Select ‘PSTN programming’.
7. Press the Scroll Down Key (Ô) until ‘CND Detection' is
displayed.
8. Select 'CND Detection' The lines with 'CND Detection'
programmed are indicated with a .
Programming Dialtone Detection
This feature is provided as a programmable option under PSTN
programming and is enabled to prevent the system from
dropping the line when dial tone has not been detected. When
enabled AND dial tone is not detected ,the line is only released
if no digit is dialed and the "Dialing time-out timer" is activated
1. From the Programming Station, press the PROGRAM Key
2. Press the Scroll Down Key (Ô) until ‘System programming’
is displayed.
3. Select ‘System programming’.
4. Enter the System Programming Password and select
‘Lines’.
5. Press the Scroll Down Key (Ô) until ‘PSTN programming’ is
displayed.
6. Select ‘PSTN programming’.
7. Press the Scroll Down Key (Ô) until ' Dialtone detection' is
displayed.
8. Select ' Dialtone detect' The lines with ' Dialtone detection'
enabled are indicated with a .