Owner`s manual
169
2. Enter the System Programming Password and select
“System”.
3. Press the scroll down key until ‘Timers’ is shown
4. Select “Timers”.
5. Press the scroll down key until ‘Notification Interval’ is
shown
6. Select “Notification Interval”.
7. Enter the value between 60 and 900 seconds and press
“Confirm”.
Call Recording
Those stations allowed to record calls are set via system
programming.
1. From the Programming station, press the PROGRAM key.
2. Press the Scroll Down key (Ô) until “System Programming”
is displayed.
3. Select “System Programming”.
4. Enter the System Programming Password and select
‘Station’.
5. Scroll down and select ‘Call Recording’.
6. Select those stations that are to be allowed record calls.
Voicemail Capacity
You change the message capacity of Mailboxes from the
default of 20 messages per Mailbox to a higher or lower amount
from 10 to 50 depending on demand.
1. From the Programming station, press the PROGRAM key.
2. Press the Scroll Down key (Ô) until “System Programming”
is displayed.
3. Select “System Programming”.
4. Enter the System Programming Password and select
‘System’.
5. Press the Scroll Down Key (Ô) until ‘VM capacity’ is
displayed.
6. Select ‘VM capacity’
7. Enter the maximum number of messages to be stored per
Mailbox.
8. Press the Hands-free Key to finish programming.
Voice Mail capacity % used
This feature tells the Administrator when the Voice Module
capacity is approaching it's limit. When the voice module
storage reached 88% of it's total capacity the system will display
on the top line of station 20 the message 'ALARM MAIL
ALMOST FULL'. This text will remain on the display until the
capacity falls below the 88% mark again. This allows the
administrator to remind user to delete old or unwanted voice
mails to free up some storage time.
The Administrator can also view the % capacity used by
individual voice boxes or the system box. To view this
1. From the Programming station, press the PROGRAM key.
2. Press the Scroll Down key (Ô) until “System Programming”
is displayed.
3. Select “System Programming”.
4. Enter the System Programming Password and select
‘System’.