Discovering Devices Manually with Auto-Link
Devices can be discovered manually by configuring the auto-link settings
on the AOS network products. Connect to the device through console,
Telnet, or secure shell (SSH) as described in the quick start guide that
shipped with the unit or available online at http://www.adtran.com. Once
auto-link is enabled and configured on the device, it will check in with the
server and become a managed device. Enter the following configuration in
the command line interface (CLI):
1. Enter the n-Command MSP server IP address to manage the device:
(config)#auto-link server <ip address | hostname>
where <ip address | hostname> is the host name or IP address of the
MSP server. IP addresses should be expressed in dotted decimal
notation (for example, 10.10.10.1).
2. Optionally specify the interval (in seconds) between attempts to contact
the n-Command MSP server:
(config)#auto-link recontact-interval <value>
By default, the AOS device will contact the server every 3600
seconds. A recontact interval of less than 3600 seconds is not
recommended. Specifying an interval of 0 seconds disables the
recontact feature.
3. Enable auto-link on the AOS device by entering the auto-link
command from the Global Configuration mode prompt.
For example,
(config)#auto-link
Additional information about configuring the auto-link feature on the AOS
device is available in the configuration guide Configuring Auto-Link for
AOS and n-Command MSP, available online from the ADTRAN Support
Forum at http://supportforums.adtran.com.
ADTRAN n-Command MSP v6.1 Help