System information
G2T Programmers Guide Rev-A 17-Nov-2014
96
10.2. Communications
Communication problems are usually the result of improper system
or host settings, or system configuration compatibility.
The IP and port address for the system are different when
communicating with Ethernet and serial communications. Verify
that the correct IP and port address are entered. Verify that the
communications cable is connected to the proper port.
System configuration compatibility issues arise when attempting to
communicate with a system using the wrong operating mode. The
switching system can be enabled in AUTO-ROUTE mode or
GANGED mode. Verify that the operating mode is set correctly.
The AUTO-ROUTE mode automatically routes the command entry
to the system without the need to address a specific module
number. Tri-Stage⢠or Output End-to-End systems are configured
in AUTO-ROUTE mode.
The GANGED mode does not require a specific module number to
route correctly the command entry. Parallel systems may be
configured in GANGED mode.