System information

G2T Programmers Guide Rev-A 17-Nov-2014
82
8.5.4.2. connectionTable
The optional connectionTable object may be used to query the
status of the switching systems crosspoint configuration by right
clicking on the object and selecting Table View,
The Query Results window displays a table where:
Output Index: Lists all output numbers
Pole0: Lists the inputs that are connected to the
corresponding outputs as seen by pole0.
See Section 6.2.4 for more details. A zero
indicates that the output is not connected
to any input. If the system has additional
poles, there will be additional “pole”
columns.
Module1: Lists the inputs that are connected to the
corresponding outputs on module 1. If the
system has additional modules, there will be
additional “module” columns.
In the example below, input 1 is connected to output 2; input 3 is
connected to output 5, etc.