System information
G2T Programmers Guide Rev-A 17-Nov-2014
78
In the Select Instance dialog box, double click on 0.0.0.0
In the Set dialog box, the default Syntax drop down should be set
to IP address. In the Value field, type in the IP address of the trap
host you want to add then select OK. The Query Results window
should show that the trap host was added successfully.
At this point, all settings are complete to begin using the SNMP
interface to communicate with the switching system.
8.5.2. sysSettings.MIB
The sysSettings.MIB is displayed in the MIB Tree. It includes a
corresponding list of OID’s to the GET and SET value table (Section
5.2.3). Depending on the purpose of the function, it may be read
only or read-write. The sysSettings.MIB is common to all SNMP
supported Universal Switching products.
You may right click on any parameter and select get to send the
query and retrieve the result. In the example below, we send a get
query to the outputs OID. The system returns that there are 64
available outputs.