System information

G2T Programmers Guide Rev-A 17-Nov-2014
72
8.1.2.2. USB (2.0)
The USB connector on the C3-001 supports version 2.0 and is Type-
A. It may be used as a remote control port to interface with a PC
using a terminal program such as Hyperterminal.
It may also be used to interface with a GPIB to USB adapter.
Universal Switching Corporation has confirmed compatibility with
the Prologix, LLC GPIB-USB Controller 6.0. More information on the
adapter is available at the manufacturer’s web site:
http://prologix.biz/gpib-usb-controller.html
8.2. Firmware Updates
The C3-001 CPU may be updated over Ethernet. This new feature
negates the requirement of additional cabling and allows for
firmware updates to systems in unmanned locations.
If a firmware update is available or requested, a complete
firmware upgrade package will be made available on our support
forum website uswi247.com
. The upgrade package contains all
the files and instructions required to update the CPU’s firmware
driver. Email Technical Support at
support@uswi.com or call at +1
(818) 381-5111 for firmware requests or assistance.
8.3. Restore to Factory Defaults
The below procedure will clear the CPU memory and restore the
CPU to its factory default settings:
1. On the front keypad, enter STORE 267 ENTER.
Displays: “KEYPAD UNLOCKED”
2. On the front keypad, enter MENU Lock Screen 7671
ENTER.
Displays: “SET OK”
3. Cycle power to the system. Note that if the system receives
another command from either the front keypad or remote
interface before the power has been cycled or in between
steps, the procedure needs to be restarted from the
beginning.